CE Certification  PCR System Factory – COVID-19 test kit (colloidal gold)-25tests/kit – CILIANG

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our outstanding administration, powerful technical capability and strict top quality handle procedure, we go on to provide our purchasers with reliable good quality, reasonable selling prices and excellent services. We goal at becoming certainly one of your most responsible partners and earning your gratification for Diagnostic Test Kit, Blue Medical Film, Self Sterilization Pouch, Our merchandise are widely recognized and dependable by users and can meet continuously building economic and social needs.
CE Certification  PCR System Factory – COVID-19 test kit (colloidal gold)-25tests/kit – CILIANG Detail:

Please flow the instruction leaflet carefully

INTENDED USE

Rapid SARS-CoV-2 Anigen Tet Card is n immunochromatography  based one step in vitro test. it is designed for the rapaid qualitative determination of SARS-cOv-2 virus antigen in anterior nasal swabs from individuals suspected of COVID-19 within the seven days of symptom onset. Rapid SARS-Cov-2 antigen Test Card shall  not be used as sole basis to diagnose or exclude SARS-CoV-2 infection.Children under 14years of age should be assister by an aduit.

SUMMARY

The novel coronaviruses belong to the B ‘genus.COVID-19 is an acute respiratory infectious disease.People are generally susceptible.Currently,the atients infected by the novel coronavirus are the main source of infection,asymptomatic infected people can also be an infectious source.Based on the current epidemiological investigation,the incubation period is 1 to 14 days,mostly 3 to 7 days.The main manifestations include fever,fatigue and dry cough.
Nasal congestion,runny nose,sore throat, myalgia and diarrhea are found in a few cases.

MATERIALS PROVIDED

Components For1 TestBox For 5 Tess/Box For 20 Tests/Box
Rapid SARS-COV-2 Antigen Test Cand (sealed fa pouch) 1 5 20
Slerile swab 1 5 20
Edracian tube 1 5 20
Sample extraction bufler 1 5 20
Instucians for use (is eafed) 1 1 1
Tube stand 1 (packaging) 1 1
Sens itivity 98.77%
Specificity 99,20%
Accuracy 98,72%

A feasibility study demonstrated that:
- 99,10% of non-professionals carried out the test without requiring assistance
- 97,87% of the different types of results were interpreted correctly

INTERFERENCES

None of the following substances at the tested concentration showed any interference with the test.
Whole Blood:1%
Alkalol:10%
Mucin:2%
Phenylephrine:15%
Tobramycin:0,0004%
Oxymetazoline:15%
Cromolyn:15%
Benzocaine:0,15%
Menthol:0,15%
Mupirocin:0,25%
Zicam Nasal Spray:5%
Fluticasone Propionate:5%
Oseltamivir Phosphate:0,5%
sodium chloride:5%
Human Anti-mouse Antibody (HAMA):
60 ng/mL
Biotin:1200 ng/mL

IMPORANT INFORMATION BEFORE THE EXECUTION

1.Read this instruction guide carefully.

2. Do not use the product beyond the expiration date.

3.Do not use the product if the pouch is damaged or the seal is broken.

4. Store the test device at 4 to 30°C in the original sealed pouch. Do Not Freeze.

5.The product should be used at room temperature (15°C to 30°C). If the product has been stored in a cool area (less than 15°C), leave it at normal room temperature for 30 minutes before using.

6.Handle all specimens as potentially infectious.

7.Inadequate or inappropriate specimen collection, storage, and transport may yield inaccurate test results.

8. Use the swabs included in the test kit to ensure optimal performance of the test.

9. Correct specimen collection is the most important step in the procedure. Make sure to collect enough specimen material (nasal secretion) with the swab, especially for anterior nasal sampling.

10. Blow the nose several times before collecting specimen.

11. The specimens should be tested as soon as possible after collection.

12. Apply the drops of test specimen only to the specimen well (S).

13. Too many or too few drops of extraction solution can lead to an invalid or incorrect test result.

14. When used as intended, there should not be any contact with the extraction buffer. In case of contact with skin, eyes, mouth or other parts, rinse with clear water. If an irritation persists, consult a medical professional.

15. Children under 14 years of age should be assisted by an adult.

Sars-cov-2 antigen rapid detection card green box 25 people


Product detail pictures:

CE Certification  PCR System Factory –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

CE Certification  PCR System Factory –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

CE Certification  PCR System Factory –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

CE Certification  PCR System Factory –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures


Related Product Guide:

We emphasize progress and introduce new solutions into the market each year for CE Certification  PCR System Factory – COVID-19 test kit (colloidal gold)-25tests/kit – CILIANG, The product will supply to all over the world, such as: Nigeria, Johor, kazakhstan, Our market share of our products and solutions has greatly increased yearly. If you are interested in any of our products or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future. We've been looking forward to your inquiry and order.
  • The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Jo from Swedish - 2018.02.12 14:52
    We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Alexia from Cannes - 2018.11.22 12:28

    Related Products