Our mission is to become an innovative supplier of high-tech digital and communication devices by providing value added design, world-class manufacturing, and service capabilities for Pharmaceutical Packaging, Disposable Medical Paper, Biobase Real-Time Quantitative PCR Bk-96p Test Machine, We are sincerely looking forward to cooperate with buyers all around the world. We imagine we will satisfy you. We also warmly welcome shoppers to visit our organization and purchase our merchandise.
OEM Rapid Diagnostic Test Manufacturer – COVID-19 test kit (colloidal gold)-25tests/kit – CILIANG Detail:

Please flow the instruction leaflet carefully

INTENDED USE

Rapid SARS-CoV-2 Anigen Tet Card is n immunochromatography  based one step in vitro test. it is designed for the rapaid qualitative determination of SARS-cOv-2 virus antigen in anterior nasal swabs from individuals suspected of COVID-19 within the seven days of symptom onset. Rapid SARS-Cov-2 antigen Test Card shall  not be used as sole basis to diagnose or exclude SARS-CoV-2 infection.Children under 14years of age should be assister by an aduit.

SUMMARY

The novel coronaviruses belong to the B ‘genus.COVID-19 is an acute respiratory infectious disease.People are generally susceptible.Currently,the atients infected by the novel coronavirus are the main source of infection,asymptomatic infected people can also be an infectious source.Based on the current epidemiological investigation,the incubation period is 1 to 14 days,mostly 3 to 7 days.The main manifestations include fever,fatigue and dry cough.
Nasal congestion,runny nose,sore throat, myalgia and diarrhea are found in a few cases.

MATERIALS PROVIDED

Components For1 TestBox For 5 Tess/Box For 20 Tests/Box
Rapid SARS-COV-2 Antigen Test Cand (sealed fa pouch) 1 5 20
Slerile swab 1 5 20
Edracian tube 1 5 20
Sample extraction bufler 1 5 20
Instucians for use (is eafed) 1 1 1
Tube stand 1 (packaging) 1 1
Sens itivity 98.77%
Specificity 99,20%
Accuracy 98,72%

A feasibility study demonstrated that:
- 99,10% of non-professionals carried out the test without requiring assistance
- 97,87% of the different types of results were interpreted correctly

INTERFERENCES

None of the following substances at the tested concentration showed any interference with the test.
Whole Blood:1%
Alkalol:10%
Mucin:2%
Phenylephrine:15%
Tobramycin:0,0004%
Oxymetazoline:15%
Cromolyn:15%
Benzocaine:0,15%
Menthol:0,15%
Mupirocin:0,25%
Zicam Nasal Spray:5%
Fluticasone Propionate:5%
Oseltamivir Phosphate:0,5%
sodium chloride:5%
Human Anti-mouse Antibody (HAMA):
60 ng/mL
Biotin:1200 ng/mL

IMPORANT INFORMATION BEFORE THE EXECUTION

1.Read this instruction guide carefully.

2. Do not use the product beyond the expiration date.

3.Do not use the product if the pouch is damaged or the seal is broken.

4. Store the test device at 4 to 30°C in the original sealed pouch. Do Not Freeze.

5.The product should be used at room temperature (15°C to 30°C). If the product has been stored in a cool area (less than 15°C), leave it at normal room temperature for 30 minutes before using.

6.Handle all specimens as potentially infectious.

7.Inadequate or inappropriate specimen collection, storage, and transport may yield inaccurate test results.

8. Use the swabs included in the test kit to ensure optimal performance of the test.

9. Correct specimen collection is the most important step in the procedure. Make sure to collect enough specimen material (nasal secretion) with the swab, especially for anterior nasal sampling.

10. Blow the nose several times before collecting specimen.

11. The specimens should be tested as soon as possible after collection.

12. Apply the drops of test specimen only to the specimen well (S).

13. Too many or too few drops of extraction solution can lead to an invalid or incorrect test result.

14. When used as intended, there should not be any contact with the extraction buffer. In case of contact with skin, eyes, mouth or other parts, rinse with clear water. If an irritation persists, consult a medical professional.

15. Children under 14 years of age should be assisted by an adult.

Sars-cov-2 antigen rapid detection card green box 25 people


Product detail pictures:

OEM Rapid Diagnostic Test Manufacturer –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

OEM Rapid Diagnostic Test Manufacturer –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

OEM Rapid Diagnostic Test Manufacturer –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures

OEM Rapid Diagnostic Test Manufacturer –  COVID-19  test kit (colloidal gold)-25tests/kit – CILIANG detail pictures


Related Product Guide:

We are commitment to offer you the aggressive price tag ,exceptional products and solutions high-quality, as well as fast delivery for OEM Rapid Diagnostic Test Manufacturer – COVID-19 test kit (colloidal gold)-25tests/kit – CILIANG, The product will supply to all over the world, such as: Curacao, Hyderabad, Curacao, Since the establishment of our company, we've realized the importance of providing good quality goods and the best before-sales and after-sales services. Most problems between global suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question points they do not understand. We break down these barriers to ensure you get what you want to the level you expect, when you want it.
  • Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Arthur from Georgia - 2018.11.11 19:52
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By mary rash from Provence - 2018.09.21 11:44

    Related Products