OEM Rapid Pregnancy Test Kit Factory – COVID-19 Antigen Rapid Test Kit – CILIANG
OEM Rapid Pregnancy Test Kit Factory – COVID-19 Antigen Rapid Test Kit – CILIANG Detail:
(Colloidal Gold)-1test/kit [saliva collection]
Test Methods
The test method was colloidal gold. Please read the manual and the instrument operation manual carefully before use.
1.Open the package and take out the test card.
2.Place the extraction tube(include collected saliva) into the Tube Holder of the carton.
3.Open the lid and draw a tube of liquid with a disposable dropper. Drop 2 drops into the sample well of the test card and start the timer.
4.Read the results within 20 minutes. Strong positive results can be reported within 20 minutes, however, negative results must be reported after 20 minutes, and the results after 30 minutes are no longer valid.
Result Interpretation
Negative result: if there is only a quality control line C, the detection line is colorless, indicating that SARS-CoV-2 antigen has not been detected and the result is negative.
Negative result indicates that the content of the SARS-CoV-2 antigen in the sample is below the limit of detection or no antigen. Negative results should be treated as presumptive, and do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions, including infection control decisions. Negative results should be considered in the context of a patient’s recent exposures, history, and the presence of clinical signs and symptoms consistent with COVID-19, and confirmed with a molecular assay, if necessary, for patient management.
Positive result: if both the quality control line C and the detection line appear, SARS-CoV-2 antigen has been detected and the result is positive for antigen.
The positive results indicate the existence of SARS-CoV-2 antigen. It should be further diagnosed by combining the patient’s history and other diagnostic information. The Positive results do not rule out bacterial infection or co-infection with other viruses. Pathogens detected are not necessarily the main cause of disease symptoms.
Invalid result: if the quality control line C is not observed, it will be invalid regardless of whether there is detection line (as shown in the figure below), and the test shall be conducted again.
The invalid result indicates that the procedure is not correct or that the test kit is out of date or invalid. In this case, the package insert should be read carefully and repeat.
The test with a new test device. If the problem persists, discontinue using the test kit of this Lot number immediately and contact your local distributor.
Product detail pictures:
Related Product Guide:
We constantly carry out our spirit of ''Innovation bringing advancement, Highly-quality guaranteeing subsistence, Administration selling advantage, Credit rating attracting buyers for OEM Rapid Pregnancy Test Kit Factory – COVID-19 Antigen Rapid Test Kit – CILIANG, The product will supply to all over the world, such as: Islamabad, Russia, Ghana, Whether selecting a current product from our catalog or seeking engineering assistance for your application, you can talk to our customer service center about your sourcing requirements. We are looking forward to cooperating with friends from all over the world.
By Colin Hazel from Honduras - 2017.09.16 13:44
This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
By ron gravatt from Munich - 2018.09.19 18:37